Welcome, Guest. Please Login or Register
Clusterheadaches.com
 
Search box updated Dec 3, 2011... Search ch.com with Google!
  HomeHelpSearchLoginRegisterEvent CalendarBirthday List  
 





Page Index Toggle Pages: 1
Send Topic Print
High flow demand valve system? (Read 7033 times)
slacker032
CH.com Old Timer
****
Offline




Posts: 325
Los Angeles, CA
Gender: male
High flow demand valve system?
Sep 9th, 2011 at 3:41am
 
So I've been using E tanks with the Op2timask at 25 lpm and it's just not cutting it anymore.  What parts would I need for a high flow (up to 60 lpm) set-up on an E-tank with a demand valve system and where's the cheapest place to get them?
Back to top
  
 
IP Logged
 
wimsey1
CH.com Alumnus
***
Offline


I Love CH.com!


Posts: 2457
MA
Gender: male
Re: High flow demand valve system?
Reply #1 - Sep 9th, 2011 at 8:38am
 
I bought mine from Lifegas, but it wasn't cheap. Might be a cheaper place. You need the demand flow valve itself with a DISS fitting...that's the type that screws onto the post you see sticking down next to where you've been hooking up to your "Christmas tree" connector. When I ordered mine I called a representative who stayed with me while she made sure I got all I needed to hook up as soon as the stuff came in. I was amazed at the results. Hyperventilating is so much easier with this rig. Batch may have some other ideas about where to get what you need. I pray for and wish you the best in this. God bless. lance
Back to top
  
 
IP Logged
 
Brew
CH.com Sponsor
CH.com Alumnus
***
Offline




Posts: 14163
Re: High flow demand valve system?
Reply #2 - Sep 9th, 2011 at 10:08am
 
E-bay.
Back to top
  

"I have been asked if I have changed in these past 25 years. No, I am the same. Only more so."  --Ayn Rand
 
IP Logged
 
slacker032
CH.com Old Timer
****
Offline




Posts: 325
Los Angeles, CA
Gender: male
Re: High flow demand valve system?
Reply #3 - Sep 9th, 2011 at 11:11am
 
Thanks for the info. After thinking about it some more, I think I should just get a higher flow regulator first to make sure it'll work for me.  Then if it does, I can swing for the demand valve.

Tried searching for a regulator that goes up to 60 lpm on ebay but no dice.  Can someone point me in the right direction?
Back to top
« Last Edit: Sep 9th, 2011 at 11:12am by slacker032 »  
 
IP Logged
 
Brew
CH.com Sponsor
CH.com Alumnus
***
Offline




Posts: 14163
Re: High flow demand valve system?
Reply #4 - Sep 9th, 2011 at 2:27pm
 
Search posts by a member named Batch.
Back to top
  

"I have been asked if I have changed in these past 25 years. No, I am the same. Only more so."  --Ayn Rand
 
IP Logged
 
slacker032
CH.com Old Timer
****
Offline




Posts: 325
Los Angeles, CA
Gender: male
Re: High flow demand valve system?
Reply #5 - Sep 9th, 2011 at 5:26pm
 
Thanks Brew.  So it looks like a Flotec regulator is my only option?  $190 is pretty steep.
Back to top
  
 
IP Logged
 
Jeannie
CH.com Sponsor
***
Offline


Live, Laugh, Love....


Posts: 2333
St Louis, Missouri
Gender: female
Re: High flow demand valve system?
Reply #6 - Sep 9th, 2011 at 5:53pm
 
Multimedia File Viewing and Clickable Links are available for Registered Members only!!  You need to Login or Register


I use this on my M tanks.  Works great!  Much better than my 25lpm reg.   Maybe you can get set up with some M's.
Back to top
  

"It's all a grand illusion when you think you're in control." ~ Kenny Chesney
 
IP Logged
 
slacker032
CH.com Old Timer
****
Offline




Posts: 325
Los Angeles, CA
Gender: male
Re: High flow demand valve system?
Reply #7 - Sep 9th, 2011 at 5:55pm
 
Jeannie wrote on Sep 9th, 2011 at 5:53pm:
Multimedia File Viewing and Clickable Links are available for Registered Members only!!  You need to Login or Register


I use this on my M tanks.  Works great!  Much better than my 25lpm reg.   Maybe you can get set up with some M's.


Unfortunately, the provider I use (Lincare) only has E tanks.
Back to top
  
 
IP Logged
 
Batch
CH.com Alumnus
***
Offline


Control The Beast With
O2 & D3 You Must


Posts: 3708
Bremerton, WA
Gender: male
Re: High flow demand valve system?
Reply #8 - Sep 10th, 2011 at 12:10pm
 
Slacker,

If possible, try to find another home oxygen provider that carries the cast iron M-size oxygen cylinders or the aluminum M or smaller M60.  If you're having an average of 3 CH a day/24 hours, you really need to have 3 of the M-size oxygen cylinders on hand for a one month's supply.  The E-size oxygen cylinders are great for local travel and work but as they're only good for three aborts, you'll need a lot of them as you've probably already figured out. 

At an average cost of $20 before insurance for an E-size oxygen cylinder (708 liters), the cost/abort is $6.67  An M-size oxygen cylinder that holds 3995 liters and costs around $30 before insurance, but you'll get 25 to 30 aborts so your cost/abort is $1.00 - $1.20.

The Flotec InGage™ regulator is the only medical oxygen regulator I've found that delivers at greater flow rates than 25 liters/minute.  Mine has higher flow rate settings for 15, 25, 40 and 60 liters/minute.  If you go this route, order the InGage™ regulator with a DISS fitting just in case you want to use a demand valve at a later date.

You can always use the less expensive welder's oxygen regulator but they're rated in psi and not in liters/minute so you'll need to figure out what psi delivers oxygen at a high enough flow rate for a fast aborts.  This is usually a high enough flow rate to hyperventilate all the way to the abort without getting too pooped out... Then remember the psi setting.

The other thing you need to do is use a breathing technique called breathing at forced vital capacity tidal volumes...  If used properly, a flow rate of 25 liters/minute should work effectively...  and by working effectively, I mean you'll experience the symptoms of paresthesia and your abort will be much faster.

The most effective breathing technique to use in order to hyperventilate effectively when using oxygen therapy as an abortive for cluster headache involves breathing as deeply as possible at forced vital capacity tidal volumes. 

Tidal volume is the lung volume representing the normal volume of air or oxygen displaced between normal inspiration and expiration when extra effort is not applied...

I'll explain...  The critical part of the respiration cycle using this method of oxygen therapy is exhalation.  You need to stand to give your diaphragm a full range of motion and lean against a wall (you will get dizzy and if you feel too dizzy, sit erect in an upright chair). Open your mouth and drop your jaw like saying the word "Haw" and exhale forcibly until it feels like there's no breath left to exhale...  there is... 

At that point do an abdominal crunch like doing sit-ups and hold the chest and abdominal squeeze until your exhaled breath makes a wheezing sound for a couple seconds.  The crunch will squeeze out another half to a full liter of breath. 

Then without delay, inhale rapidly until it feels like your lungs can't hold any more... then repeat the forced exhalation with a crunch.   Repeat this sequence without hesitating between inhalation and exhalation and keep repeating it until the pain is completely gone.

Three things will happen when you use this breathing technique.  The first thing is you'll start coughing...  this is normal and the coughing will clear in 5 to 10 seconds.  This is why you can take your time with the first 3 to 4 breaths using this procedure and breathing technique.  When the coughing clears, you can start increase the respiration rate.

The second thing that will happen is you'll start to experience the symptoms of paresthesia after three to five respiration cycles using this breathing technique.  The symptoms of paresthesia include a very slight tingling or prickling of the fingertips, lips, or back of the neck with no apparent long-term physical effect.  You'll also experience a slight dizziness.

Strange as it may sound, the symptoms of paresthesia are your friend and they are the best indication you're breathing correctly for the fastest abort of your CH as possible.  As you are using this breathing technique to voluntarily hyperventilate, the symptoms of paresthesia will clear in 10 to 15 seconds after you return to a normal respiration rate.

The third thing that will happen is you'll get tired.  If you're executing this breathing technique properly, it's hard work...  but well worth the effort.

The reason for using this breathing technique is simple.  It's the most effective way to push your system into respiratory alkalosis as fast as possible.  As the last volume of exhaled breath exhaled (the end tidal flow), contains the highest concentration of CO2, using this breathing technique will pump CO2 from your lungs through exhaled breath faster than your body generates it through normal metabolism.

Lowering CO2 levels with this breathing technique elevates your arterial pH making it more alkaline, hence the name respiratory alkalosis.  This condition stimulates vasoconstriction of the arteries and capillaries in an around the trigeminal ganglion to start the abort process.   

This is an important bio-mechanical step in the process of aborting a cluster headache as narrowing of the blood vessels resulting from contraction of the muscular wall of the vessels counteracts the vasodilation associated with the cluster headache syndrome that's causing all the pain. 

If you think about it, sumatriptan succinate (imitrex, imigran) or any of the other family of triptans do the same thing... only they carry some onerous side effects and costs a lot more per abort than oxygen...

If you're still having trouble aborting your CH using this technique with an oxygen flow rate of 25 liters/minute, you might want to consider trying the anti-inflammatory regimen.  It can help reduce abort times and if you stay on this regimen long enough, like two to three weeks, it can also prevent most if not all of your cluster headaches. 

To date, based on reports back from CH'ers who have started this regimen, it's proving to be 75% effective with a ±15% margin of uncertainty in preventing cluster headaches.

Hope this helps.

Take care,

V/R, Batch
Back to top
  

You love lots of things if you live around them. But there isn't any woman and there isn't any horse, that’s as lovely as a great airplane. If it's a beautiful fighter, your heart will be ever there
pete_batcheller  
IP Logged
 
B.Baer
CH.com Veteran
***
Offline


I Love CH.com!


Posts: 154
Northeast Pennsylvania
Gender: male
Re: High flow demand valve system?
Reply #9 - Sep 10th, 2011 at 12:24pm
 
Seems to me that Lifegas was going to offer a more economical Demand Valve system. I bought mine years ago, and have not kept up on the new ones.

I'd check with Lifegas and see if they have a less expensive option, as I've had no problems with mine and can attest that they make a very good quality product.

I wish I could be of more help, but that's the only experience I've had with Demand Valves. Well worth the money, when you can swing it, at least it was for me, I know they are not inexpensive.

The M tanks are great for home use , good luck and keep us posted. Insurance and providers are sometimes difficult but just keep working at it.

All the best,

Baer

I have no affiliation with Lifegas other than being a very satisfied customer...
Back to top
  
Barry Baer  
IP Logged
 
slacker032
CH.com Old Timer
****
Offline




Posts: 325
Los Angeles, CA
Gender: male
Re: High flow demand valve system?
Reply #10 - Sep 10th, 2011 at 3:06pm
 
Baer - I sent LifeGas an email.  Thanks.

Thanks Batch. I'll try to look for a company that provides M tanks in southern California.
Back to top
  
 
IP Logged
 
Page Index Toggle Pages: 1
Send Topic Print

DISCLAIMER: All information contained on this web site is for informational purposes only.  It is in no way intended to be used as a replacement for professional medical treatment.   clusterheadaches.com makes no claims as to the scientific/clinical validity of the information on this site OR to that of the information linked to from this site.  All information taken from the internet should be discussed with a medical professional!